Set the voltage setting of the insulation resistance tester to 500v.
Electric motor megger test procedure.
In using the megger a bit of a learning curve is involved.
Clamp the alligator clip on one of the megger probes to the wire or cable touch the other probe to the exposed conductor and press the test button.
As motors age the current drawn generally rises because winding insulation resistance drops.
Set the voltage level of the insulation resistance tester to 500v.
The correct settings connection procedures test durations and safety precautions must be implemented to avoid damaging the equipment or possible electrocutions.
Test inter phase resistance by disconnecting the leads from each terminal with a flathead screwdriver then touch any two terminals with the two probes.
For a three phase motor the isolation resistance can usually be measured between each motor winding or phase and between each motor stage and motor frame earth by an insulation tester or megger 4.
Using the megger to test a three phase motor is rather easy though the safety hazards for this procedure are quite high.
Temperature humidity moisture and dust particles.
You can test your motor insulation with the help of a megger.
The megger will generate a current between the probes and the meter will record the resistance of the jacket to the flow of the current.
The megger insulation tester is essentially a high range resistance meter ohmmeter with a built in direct current generator.
This is important because the high voltage current in three phase systems is far more lethal than a mere low voltage shock received in residential setting.
Be sure to follow good safety measures to prevent electrical shock.
For a three phase motor insulation resistance is usually measured between each motor winding or phase and between each motor phase and motor frame earth using an insulation tester or megger.
Compare the reading to documented or nameplate specifications.
The motor under test must be powered down and disconnected from all equipment and wiring not included in the test.
The megger test is a method of testing making use of an insulation tester resistance meter that will help to verify the condition of electrical insulation.
For good insulation the resistance usually reads in the megohm range.
The basic procedure is to measure the start up and running current for any motor while it s connected to a load.
The megger insulation tester is a small portable instrument that gives you a direct reading of insulation resistance in ohms or megohms.
Maintain contact for 30 to 60 seconds to get a reliable reading.
The ideal mode of testing is phase to phase and phase to ground.
Insulation resistance quality of an electrical system degrades with time environment condition i e.
Any reading over 1 meg ohm is sufficient.
Crank the megger and notice the reading.